Specification Specifications according to ISO 10360-2:2009, ISO 10360-5:2010 and ISO 10360-4:2000 Temperature Range Temperature Range Temperature Range Probe 18 ÷ 22 °C 16 ÷ 26 °C 15 ÷ 30 °C Configuration E E/ 0,MPE 150,MPE PFTU,MPE MPETHP/t E E/ 0,MPE 150,MPE PFTU,MPE MPETHP/t E E/ 0,MPE 150,MPE PFTU,MPE MPETHP/t DEA GLOBAL Silver SF 09.xx.08 HP-S-X3C/X5 1.4 + L/333 1.4 2.5/45 1.4 + L/285 1.4 2.5/45 1.4 + L/256 1.4 2.5/45 HH-A, HH-AS/HP-S-X1S, H 1.4 + L/333 1.4 2.5/45 1.4 + L/285 1.4 2.5/45 1.4 + L/256 1.4 2.5/45 HH-A, HH-AS/TP200 1.9 + L/333 1.9 – 1.9 + L/285 1.9 – 1.9 + L/256 1.9 – HH-A, HH-AS/HP-T, HP-TM 2.1 + L/333 2.0 – 2.1 + L/285 2.0 – 2.1 + L/256 2.0 – DEA GLOBAL Silver SF 12.xx.10 HP-S-X3C/X5 2.1 + L/333 1.8 3.1/45 2.1 + L/277 1.8 3.1/45 2.1 + L/250 1.8 3.1/45 HH-A, HH-AS/HP-S-X1S, H 2.1 + L/333 1.8 3.1/45 2.1 + L/277 1.8 3.1/45 2.1 + L/250 1.8 3.1/45 HH-A, HH-AS/TP200 2.5 + L/333 2.2 – 2.5 + L/277 2.2 – 2.5 + L/250 2.2 – HH-A, HH-AS/HP-T, HP-TM 2.7 + L/333 2.6 – 2.7 + L/277 2.6 – 2.7 + L/250 2.6 – ProbeConfiguration R (1) O,MPL R (2) O,MPL HP-S-X3C/X5 1.2 1.7 HH-A, HH-AS/HP-S-X1S, H 1.2 1.7 HH-A, HH-AS/TP200 2.1 2.7 HH-A, HH-AS/HP-T, HP-TM 2.1 2.7 NOTE: E0, E MPE/ 150, MPE specifications are to be formally understood as E0,MPE* /E150,MPE* for the case where non-normal CTE material calibrated test lengths are used. (1)R0,MPL referred to DEA GLOBAL 09.xx.08 (2)R0,MPL referred to DEA GLOBAL 12.xx.10 Probe Configuration for performance test: Performance data are valid if the following specification are • HP-S-X3C/X5: stylus length 60 mm, tip diameter 5 mm met: • HP-S-X1S: without extension, stylus length 50 mm, tip Temperature Range 18 ÷ 22 °C diameter 5 mm Max. air temperature variation 1 °C/h - 2 °C/24h • HP-S-X1H: with an extension of 100 mm, stylus length Max. air temperature variation 1 °C/m 20 mm, tip diameter 5 mm • TP200: Standard Force Module, stylus length 10 mm, tip Temperature Range 16 ÷ 26 °C diameter 4 mm Max. air temperature variation 1 °C/h - 5 °C/24h • HP-T: Standard Force, stylus length 10 mm, tip Max. air temperature variation 1 °C/m diameter 4 mm • HP-TM: Standard Force Module, stylus length 10 Temperature Range 15 ÷ 30 °C (*) mm, tip diameter 4 mm Max. air temperature variation 1 °C/h - 5 °C/24h Max. air temperature variation 1 °C/m Dynamics: • Max. 3D Speed: 866 mm/s (*) Accuracy values under the conditions below are available on • Max. 3D Accel.: 4300 mm/s2 (1400 mm/s2 with HP-S-X3C/X5) request: • Max. Scanning Speed : 500 mm/s Temperature Range 15 ÷ 30 °C Max. air temperature variation 2 °C/h - 10 °C/24h Max. air temperature variation 1 °C/m 4 DEA GLOBAL SILVER SF | DS CMM 037/02 - EN - 07/14