Shrinking 5.2 Work sequences when gripping, releasing or changing a tool For your own safety, please observe the following rules when working with the ISG3410: Always observe the safety instructions for all shrink-fit processes! At ISG3410-TWK, after finishing the shrinking procedure, the cooling down must be operated manually through pressing the Cool button. The cooling can be operated manually at any time through pressing the Cool button. Use safety gloves! Shrinking chucks should only be handled with gloves and only at the collar and not in the heated area. The maximum contact time should not exceed 5 sec. even when using a protective glove. Wear safety goggles! 5.2.1 General advices Select the respective tool fitting (see Chapter 10.3.1 Available additions and optional accessories, page 48) for the chuck and place this on the footprint. Insert the chuck into the tool fitting. In the case of short tools to be gripped and ThermoGrip clamping chucks, you can insert the tools 5 mm deep into the front part of the clamping chucks. When the shrinking menu is selected you get an overview of all shrinking functions. October 2015 ISG3410 19