Shrinking 5.5.2 Shrinking with free “Parameter” selection: MANUAL This mode is intended for shrinking special tools or special clamping chucks, which only occur in seldom cases. Furthermore, this mode can be used to set the shrinking parameters for frequently used special chucks or tools. In order to define these as parameters, set under a custom name. Parameter Manual Tool Memory Favorites Select with up ▲ and ▼ down the function "MANUAL" and activate with OK. Step 1: Select shrinking time Select with up ▲ and ▼ down the desired shrinking time in steps of 0,5 s (0 – 60 s) Activate with OK. Step 2: Select shrinking output power Select with up ▲ and ▼ down the desired output power in steps of 5% (5% – 120%) Activate with OK. Step 3: Additional options Select with up ▲ and ▼ down additional options and activate or deactivate with OK. The symbol shows the device is ready for shrinking October 2015 ISG3410 27