Appendix Error no. Error message Possible cause Corrective measures 2.7 Telegram error Connection betweendistribution board and I/O-extension faulty Check the connections inthe device 2.8 Telegram error Connection betweendistribution board andgenerator faulty Check the connections inthe device 3.1 Generator not found at Generator not connected to Check the connections instart-updistribution boardthe device. 3.4 Invalid Data Data in set of parameterscorrupted Insert correct data into toolmemory withToolMemoryEditor Missing at least 1 phase, Check mains supply at 3.6 Current defect in IGBT mains supply is too low or mains receptacle in device breaks down during shrinking behind the fuses 3.7 Current defect in coil Current monitoring of the coils Check coil contactsdiagnosesover/ under currentChange coil Leave the coil to cool 3.8 Safety circuit open Coil temperature > 60°C down or change it Try again No coil detected 3.9 (only with an option “coil Coil absent Fit a coil change”) 3.10 Temperature of coolingblock too high to startshrinkingTemperature inside ofgenerator is too high Wait to cool downTry again 3.11 Temperature of cooling Temperature inside ofblock too highgenerator is too high Wait to cool downTry again 3.12 Relay fault Relay of output stage doesn’tclose Try again 3.13 Hardware error Invalid generator hardwaredetected Contact your supplier 3.18 Generator functionstopped too earlyError of generator Acknowledge errormessage and try again Device up and cannot be started programmed Lack of compressed (ISG3410-WK) No electric supply air Connect and/ or check thepower and compressed airsupply Acknowledge error message with Stop button. Should these measures fail to start up the ISG3410, please contact your supplier or the manufacturer’s customer service. October 2015 ISG3410 45