Appendix 10 Appendix 10.1 Error messages and corrective measures Error no. Error message Possible cause Corrective measures 1.1 No SD card detected inoperation panelSD card faulty or absent Insert SD card correctly orreplace it 1.2 Programmed coil andfitted coil are notidenticalWrong coil programmed intool memory Change programming intool memory or insert thecorrect coil No coil fitted (only with Coil absent or fit wrongan option “coil change”) Fit a coil 1.3 Temperature protection Timeout of temperature Wait 5 minutes until end ofof coil 3 activeprotection not finishedtemperature protection 1.4 Telegram error Connection betweenoperation panel anddistribution board faulty Check the connections inthe device Clean tank Remind the operator to check check coolant emulsion for 1.5 Coolant emulsion coolant emulsion for sufficient sufficient level or possibly contaminated level or contamination contamination 1.6 Chuck did position in not leave time start Position switch misadjusted/ defective Lifting unit not moving freely Check/ exchange positionswitchService/ clean/ lubricatelifting unit 1.7 Chuck did not achieveend position in timePosition switch misadjusted/defective Check/ exchange positionswitchLifting unit not moving freelyService/ clean/ lubricatelifting unit Switch on RCD 1.8 RCD been switch of released pump has Pump or RCD defective Change pump Change RCD Error occurred while shrinking Solve problem according 1.9 Error not acknowledged and has not been to error no. and acknowledged acknowledge message 1.10 Wrong type in tool Tool type wrong in set of tool See manual ofmemorymemoryToolMemoryEditor. 2.2 No USB stick indistribution boarddetectedUSB stick faulty or absent in Insert or replace USB stickdistribution boardinto distribution board 2.3 File not found on USBstick Missing file on USB stick Copy missing file on USBstick 2.4 Wrong checksumdetected in file Tool.binInvalid file Reprogram file withToolMemoryEditor 2.5 Float switch in coolant Float switch fixed or hangs Check switch/ leveltank not engagedCoolant level in tank too lowrefill coolant liquid 2.6 Invalid machine type Machine type not detectable Contact your supplier October 2015 ISG3410 44